logo
Send Message
  • English
Home ProductsInfectious Disease Test Kit

TRFIA PCT Test Kit , Antibody Fast Detection Kit CFDA Approved

Certification
China Lumigenex (Suzhou) Co. Ltd certification
China Lumigenex (Suzhou) Co. Ltd certification
I'm Online Chat Now

TRFIA PCT Test Kit , Antibody Fast Detection Kit CFDA Approved

TRFIA PCT Test Kit , Antibody Fast Detection Kit CFDA Approved
TRFIA PCT Test Kit , Antibody Fast Detection Kit CFDA Approved TRFIA PCT Test Kit , Antibody Fast Detection Kit CFDA Approved TRFIA PCT Test Kit , Antibody Fast Detection Kit CFDA Approved

Large Image :  TRFIA PCT Test Kit , Antibody Fast Detection Kit CFDA Approved

Product Details:
Place of Origin: China
Brand Name: Lumigenex
Certification: ISO13485, cFDA
Model Number: High sensitivity cFDA approved PCT Quantitative Detection Kit (TRFIA)
Payment & Shipping Terms:
Minimum Order Quantity: Negotiable
Price: Negotiable
Packaging Details: 20 tests/box
Delivery Time: depends on order quantity
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 100,000 tests/day

TRFIA PCT Test Kit , Antibody Fast Detection Kit CFDA Approved

Description
Product Name: High Sensitivity PCT Quantitative Detection Kit (TRFIA) Specification: 20 Tests/box
Certificate: ISO13485, CFDA Specimen: Whole Blood, Plasma, Serum
Storing Temperature: 2℃-8℃ Shelf Life: 18 Months
Place Of Origin: Jiangsu,China Production Capacity: 100,000 Tests/day
Technology: TRFIA OEM: Available
Highlight:

TRFIA pct test kit

,

cFDA pct test kit

,

TRFIA antibody fast detection kit

High sensitivity cFDA approved PCT Quantitative Detection Kit (TRFIA)

 

1. Product Description

Principle:

PCT test kit is based on a time-resolved fluorescence immunochromatography technology, used to quantitatively detection the concentration of PCT in blood specimens. After mixing buffer and blood specimen in reagent card, mat specimen of PCT and markers of fluorescent microsphere decoupling PCT monoclonal antibody to form complexes, and through the capillary chromatography to nitrocellulose membrane containing PCT with another specific antibody detection, and captured, form double antibody sandwich composites. So more PCT in the specimen, more compound accumulates on the test strip. The excess unreacted fluorescent microspheres were then computed to the control line. The fluorescence intensity on the detector line after the reagent strip is excited reflects the PCT content captured in the specimen. The concentration of PCT in the specimen was quantitatively reflected by the detection of time-resolved fluorescence immunoanalyzer LTRIC-600/LTRIC-300/LTRIC-1000.

Intended Use:

PCT test kit is suitable for use in vitro quantitative determination of PCT in human serum/plasma/whole blood. PCT is a very sensitive and specific blood marker, and its concentration is positively correlated with the severity of inflammation. Therefore, it can be used as a reliable indicator to judge the disease, prognosis and observation of curative effect. At present, PCT detection is mainly used for diagnosis of bacterial infection, virus infection, fungal infection and sepsis. It’s detection platform mainly includes chemiluminescence technology, immunoturbidimetry technology, colloidal gold technology, immunofluorescence technology, time-resolved fluorescence technology, etc.

 

2. Specification

Product Name High sensitivity cFDA approved PCT Quantitative Detection Kit (TRFIA)
Specification 20 tests/box
Sample Whole blood, Plasma, Serum
Storage Temperature 2℃-8℃
Certificate ISO13485/cFDA
Place of Origin Suzhou, Jiangsu, China
MOQ Negotiable, Accept small quantity
Lead Time Depends on the order, 1~15 working days
Tips Best to inquire for shipping details. We will contact you within 24 hours. Door to door service can be provided in some areas.

 

3. High sensitivity cFDA approved PCT Quantitative Detection Kit (TRFIA) Main component

  • 20 or 50 PCT Tests
  • 1 IC card
  • 1 Instruction for use
  • 20 or 50 Sample Buffer
  • Reagent card consists of plastic stuck with strip, strip by sample mat, markers mat (on the main material for glass fiber, spray has the nanometer microspheres in mice against people of PCT single fluorescent probe (solid content is 0.5%, microspheres 1:40 dilution)), detect membrane (main material for nitrocellulose membrane, spray has the person of PCT in rat monoclonal antibody (1.5 mg/mL) and sheep immunoglobulin G (IgG) of the rat polyclonal antibody (1.0 mg/mL)), absorbing mat and polystyrene (PVC) plastic panels. Specimen test fluid 450 ul/ person, mainly composed of phosphate (PBS) buffer, containing 0.5% bovine serum albumin (BSA) and 0.05% preservative Proclin-300 (the main active ingredients are 2-methyl-4-isothiazoline-3-one and 5-chloro-2-methyl-4-isothiazoline-3-one).

 

4. Storage conditions and expiry date?

  • The validity of test kit sealed in aluminum foil pouch is 18 months under condition of 2℃-8℃.
  • The sealed test kit is stable for up to 30 days under room temperature (2℃-30℃) within validity period.
  • Temperature change (< 37℃) during shipment has no effect on quality of the test kit.
  • The unsealed kit is stable within 1 hour under ambient condition.

Contact Details
Lumigenex (Suzhou) Co. Ltd

Contact Person: Bonnie

Tel: 86-13814877381

Send your inquiry directly to us (0 / 3000)