Product Details:
|
Type: | Portable | Application: | Clinical/Health Center /Hospital Etc |
---|---|---|---|
Accuracy: | Target Value±10% | Precision: | CV≤5.0% |
Linearity: | R²≥0.980 | Repeatability: | CV(%)≤15% |
Specimen: | 20-40uL Fingertip Blood | ||
High Light: | CE dry chemistry analyzer,lightweight dry chemistry analyzer,CE portable biochemistry analyzer |
Dry Biochemical Analyzer
Features of the instrument
Accuracy: Analyzer detects the relative deviation of
the accuracy of signal value should be the
target valve±10%
· Precision: CV≤5.0%
· Linear: Analyzer signal value range(10~90),
analyzer linear r2≥0.980
· Repeatability: CV(%)≤15%
· Difference between batch: CV(%)≤15%
Comparison table between the dry biochemical analyzer and wet biochemical analyzer | |||
No. | Name | Dry Biochemical Analyzer | Wet Biochemical Analyzer |
1 | Detection method | Reflection luminosity | Transmission photometry |
2 | Reaction carrier | Solid medium | Colorimetric cup or flow pool |
3 | Pipeline system | Non-liquid pipeline | yeah |
4 | Theoretical basis | Kubelka | Lambert-Beer |
5 | Maintain | Simple | Tedious |
6 | Reagent | Solid-phase, most of them do not need calibration, and the stability period is long. | Liquid, need calibration, a short stabilization period |
The advantages of dry chemistry.
High accuracy.
The sensitivity and accuracy are similar to those of typical discrete instruments.
Rapid detection.
Multilayer film technology, which can be tested immediately by adding samples, and the detection time is short.
Widely used.
Flexible use scene, suitable for laboratory departments, clinical blood stations, primary medical and health institutions, physical examination centers, etc.
Environmental protection and no pollution.
No washing, clean environmental protection waste only reagent card, easy to collect and dispose of.
Compact and lightweight.
The instrument has the advantages of simple structure, small size, and lightweight.
Easy to operate.
Non-liquid pipeline.
Storage at room temperature, no reheating, long-term stability without electrode maintenance, no need to replace electrode film.
Influencing factors of dry Chemical Analysis Technology.
1. Quality control material.
2. Storage and use of dry film reagents.
3. Working environment and temperature
Testing Parameter
Test items | Test Time/Sample Volume | Measurement Range (mmol/L) | Reference Range (mmol/L) |
TC |
2min 40µL(finger blood) |
2.59-11.70 | <5.18 |
HDL-C | 0.39-2.59 | ≥1.04 | |
TG | 0.50-6.00 | <1.70 | |
LDL-C | to be calculated value | <3.35 | |
TC/HDL-C | to be calculated value | <4.98 |
Dry Chemistry Analyzer Technology
Data management: Can storage 3000 data
Communication system: Matched USB Cable connect analyzer and computer Power supply: AA battery, 2pcs
Humidity: 20%-80%
Printer: Portable Bluetooth printer (optional) Output: USB, Bluetooth
Outside size Master: 139(L)×76(W)×26.6(H)mm, Error±1mm Weight: 116g±16g