Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen

Certification
China Lumigenex (Suzhou) Co. Ltd certification
China Lumigenex (Suzhou) Co. Ltd certification
I'm Online Chat Now

Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen

Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen
Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen

Large Image :  Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen

Product Details:
Place of Origin: China
Brand Name: Lumigenex
Certification: ISO13485, cFDA, CE
Model Number: T2010-020, T2010-050
Payment & Shipping Terms:
Minimum Order Quantity: 1250 tests
Price: USD 3.0/ Test
Packaging Details: 20 tests/box, 50 tests/box
Delivery Time: 2-10 Days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: 100,000 tests/day

Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen

Description
Product Name: Pepsinogen I / Pepsinogen II (PGI / PGII) Combo Test Kit (TRFIA) Funtion: Gastric Function Diagnose
Technology: Time Resolved Fluorescence Immunochromatographic Assay (TRFIA) Usage: Vitro Diagnostic Reagent
Format: Strip, Cassette Specimen: Whole Blood, Plasma, Serum
Storing Temperature: 2℃-8℃ Shelf Life: 18 Months
Reading Time: 15 Min. Compatible Equipment: Lumigenex TRFIA Analyzer LTRIC-600, LTRIC-1000
High Light:

Pepsinogen I Combo Test Kit

,

PGII Combo Test Kit

,

Pepsinogen II Combo Test Kit

Pepsinogen I / Pepsinogen II (PGI / PGII) Combo Test Kit Whole Blood Test Pulmonary Infection Gastric Function Diagnosis

High sensitivity cFDA approved Pepsinogen I / Pepsinogen II (PGI / PGII) Combo Test Kit (TRFIA)

 
Intended Use

The pepsinogen I/pepsinogen II detection kit (time-resolved fluorescence immunoassay) is suitable for quantifying pepsinogen I and pepsinogen in human serum, plasma, and whole blood in vitro.

The concentration and PGI/PGII ratio of pepsinogen I (abbreviated as PGI) and pepsinogen II (abbreviated as PGII) may be used to diagnose atrophic illnesses of the gastric fundus mucosa, such as superficial gastritis, erosive gastritis, gastric ulcer, duodenal ulcer, atrophic gastritis, and so on. Pepsinogen (PG) is an inactive precursor of pepsin (proteolytic enzyme) in gastric juice. It is classified into two types: pepsinogen I (PG I) and pepsinogen II (PG II) (PG II). The stomach glands emit PG I, whereas the gastric fundus gland, cardia gland, pyloric gland, and Brunner gland secrete PG II. A reduction in the number of cells secreting PG I, and Hyloric gland cell growth, are all signs of gastric mucosal atrophy. As a consequence, the PGI/PGII ratio falls.

 

Principle

The pepsinogenI/ pepsinogen II combined detection kit (time-resolved fluorescence immunochromatography) was used to quantitatively determine the concentration of pepsinogen I, and pepsinogen II in serum, plasma and whole blood based on Time Resolved Fluorescence Immunochromatographic Assay.

The sample detection solution and blood samples were mixed and added to the reagent card. The sample (PGI/PGII) was combined with the mouse anti-human pepsinogen I monoclonal antibody microsphere fluorescent probe, mouse anti-human pepsinogen II monoclonal antibody nano-microsphere fluorescent probe on the marker pad to form a complex and the monoclonal antibody containing mouse anti-human pepsinogen I, mouse anti-human pepsinogen II was detected on the nitrocellulose membrane by capillary action chromatography and captured, Form a double antibody sandwich complex (that is, monoclonal antibody-to-test-mab nano-microsphere fluorescent probe complex). As a result, the more PG, PGII in the sample, the more the double antibody sandwich complex accumulates. The excess unreacted Mono-anti-nano-microspheres fluorescence probe continued to chromatography to the control line. The fluorescence intensity on the detection line is positively correlated with the concentration of the object (PGI, PGII) in the sample, and the regression equation is calculated and written into the IC card.

The Time-Resolved Fluorescence Immunoanalyzer reads the regression equation data stored on the IC card, tests the fluorescence intensity on the detection line, and then replaces the fluorescence intensity with the regression equation for automatic calculation of the object concentration (PGI/PGII) in the output sample.

 

Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen 0Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen 1
 
Specification
 
Product Name
Pepsinogen I / Pepsinogen II (PGI / PGII) Combo Test Kit (TRFIA)
Method
Time Resolved Fluorescence Immunochromatographic Assay (TRFIA)
Certificates
ISO13495, CE
Usage
Vitro Diagnostic Reagent
Function
Gastric Function Diagnose
Specimen
Whole Blood/ Serum/ Plasma
Test Kit Components
20 / 50 Test cards
20 / 50 Sample buffer
1 IC card
1 Instruction manual
Storage & Shelf Life
Unopened test kit is stable for 18 months under 2-8℃, and up to 30 days under 2-30℃.
Temperature change (< 37℃) during shipment has no effect on quality of the test kit.
Unsealed test kit is stable within 1 hour
Compatible Equipment
Lumigenex Time-resolved Fluorescence Immunoanalyzer LTRIC-600, LTRIC-1000

 

 

Test Procedure
 
Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen 2
Performance
 
Accuracy
Deviation from the quality control target value should be within ±15%.
Minimum detection limit
no higher than 0.1ug/mL.
Linearity
(0.2-50) ug/mL, the kit correlation coefficient R≥0.99
Repeatability
Coefficient of variation (CV) ≤15%.
Inter-batch difference
Inter-batch variation coefficient (CV) ≤15%.

 

Recommended Products

Pepsinogen I / Pepsinogen II Combo Test Kit Whole Blood Specimen 3

 
Time-Resolved Fluorescence Immunoassay Analyzer
 
Product model LTRIC-600, LTRIC-1000
 
Test Menu
Cardiovascular Disease: cTnI, CK-MB, Myo, cTnI/CK-MB/MYO, H-FABP, cTnI/H-FABP, NT-proBNP, D-Dimer
Inflammation: PCT, CRP, SAA, CRP/SAA
Renal Injury: NGAL, ACR
Others: PGI/PGII, β-HCG, Influenza A+B
 
Highlights
* Nano-Enhanced TRIFA
* Rapid and accurate quantitative POCT Platform
* Repeatability: CV<10%
* Stability: σ ≤ 10% * Accuracy: Δn ≤ 10% * Linearity: r ≥ 0.99
 
Detection Projects
Test Strips and Cassettes (with links)

Diabetes

HbA1C, Glucose,  Ketone Body

Hyperlipidemia

Lipid Panel

Anemia

Hemoglobin

Cardiac

CK-MB, cTnI, Myo, NT-proBNP, D-Dimer, H-FABP, sST2, Homocysteine,

cTnI/H-FABP, cTnI/CK-MB/Myo

Inflammation

CRP,  PCT,  SAA,  CRP/SAA,  PCT/IL-6

Hormone

5(OH)D3, β-HCG, AMH

Gastric Function

PGI/PGII

Liver Injury

Aspartate Transaminase, Alanine Aminotransferase

Renal Injury

mALB, Creatinine, NGAL, ACR(TRFIA), ACR(Colloidal Gold)

Gout

Uric Acid

Others

Influenza A+B Combo, Influenza A+B/RSV Combo

Monkeypox CG, Monkeypox IgG/IgM, Monkeypox RT-PCR

 

Contact Details
Lumigenex (Suzhou) Co. Ltd

Contact Person: Bonnie

Tel: 86-13814877381

Send your inquiry directly to us (0 / 3000)