Send Message
Home ProductsPOC Test Kit

Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer

Certification
China Lumigenex (Suzhou) Co. Ltd certification
China Lumigenex (Suzhou) Co. Ltd certification
I'm Online Chat Now

Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer

Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer
Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer

Large Image :  Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer

Product Details:
Place of Origin: China
Brand Name: Lumigenex
Certification: ISO13485, cFDA, CE
Model Number: D2009-015, D2009-050, D2009-050T.
Payment & Shipping Terms:
Minimum Order Quantity: 1250 tests
Price: USD 7.0/ Test
Packaging Details: 20 tests/box, 50 tests/box
Delivery Time: 2-10 Days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: 100,000 tests/day

Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer

Description
Product Name: Aspartate Transaminase Test Strips(Dry Chemical Method) Funtion: Assess Liver Health, Diagnose And Monitor Liver Disease
Method: Dry Chemical Method Usage: In Vitro Diagnose Test In Hospital Clinic Laboratory
Format: Strip Specimen: Whole Blood/ Plasma/ Serum
Storing Temperature: 4°C ~30°C Shelf Life: 18 Months
Reading Time: 4 Min. Compatible Equipment: Lumigenex Prochek Dry Chemistry Analyzer LP-100
High Light:

CE Registered Aspartate Transaminase Test

,

Dry Chemical Analyzer Aspartate Transaminase Test

CE Registered Liver Injury Biomarker Aspartate Transaminase Test Strips Used With Dry Chemical Analyzer

Aspartate transaminase Test Strips

(Dry chemical method)

 

Intended Use

This Aspartate transferase (AST) Test Strip can quantitatively measure the AST amount in the blood specimen. AST test can help assess the liver health condition, and provide insight into other health conditions as well.
Aspartate transferase (AST) is an enzyme that’s found in the human liver, heart, pancreas, muscles, and other tissues in your body. When the cells get damaged, AST can leak into the bloodstream. Because of this, high levels of AST in a blood sample can be a sign of an underlying medical condition — most often (but not always), a liver condition.
As many types of liver conditions can cause AST levels in the blood to rise, healthcare providers don’t use the test alone to diagnose conditions. This test is mainly done along with other tests (such as ALT, ALP, and bilirubin) to diagnose and monitor liver disease.

 
It is used with Lumigenex's Pro Chek® Dry Chemistry Analyzer which provides diagnostic answers in 2 minutes.
The Dry Chemistry Analyzer should only be used by healthcare professionals for in vitro diagnostic use.

 

Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer 0Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer 1

 

 
 
Specification
Product Name
Aspartate transaminase Test Strips(Dry chemical method)
Function
Assess liver health, diagnose liver disease
Method
Dry Chemical
Format
Strip
Specimen
Whole Blood/ Plasma/ Serum
Usage
Daily use for professional testing in hospital, or home use for self-testing
Test Kit Components
15 / 50 Test cards
1 IC card
1 Instruction manual
Storage
For Aluminum foil bag package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively. Please use the test strip within 1 hour once the foil bag is open. For cylinder package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively.the test strips in cylinder are stable at 4°C ~30°C for 30 days tentatively once the cylinder package is opened.
Performance
Accuracy: Deviation from the quality control target value should be within ±15%.
Minimum detection limit: no higher than 0.1ug/mL.
Linearity : (0.2-50) ug/mL, the kit correlation coefficient R≥0.9900.
Repeatability: Coefficient of variation (CV) ≤15%.
Inter-batch difference: Inter-batch variation coefficient (CV) ≤15%.
Compatible Equipment
Lumigenex Prochek Dry Chemistry Analyzer LP-100
 

 

Performance
 
Accuracy
Deviation from the quality control target value should be within ±15%.
Minimum detection limit
no higher than 0.1ug/mL.
Linearity
(0.2-50) ug/mL, the kit correlation coefficient R≥0.99
Repeatability
Coefficient of variation (CV) ≤15%.
Inter-batch difference
Inter-batch variation coefficient (CV) ≤15%.

 

 

Certificates

 

Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer 2 Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer 3

 

Recommended Products

 

Intelligent Chronic Disease Management Expert

Dry Chemistry Analyzer LP-100

This Analyzer is a quantitative detection instrument that quickly detects the sample concentration by changing the color of the test strip. It suits for solid phase carrier reagents which is used for rapid and quantitative analysis of the concentration of various analytes in blood specimen.

Features:

Designed for POC Testing
Portable handheld
Large, easy-to-read LCD
Stores up to 500 results/ test item

Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer 4

Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer 5

Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer 6Liver Injury Biomarker Aspartate Transaminase Test Strips With Dry Chemical Analyzer 7

 
 

 

Contact Details
Lumigenex (Suzhou) Co. Ltd

Contact Person: Bonnie

Tel: 86-13814877381

Send your inquiry directly to us (0 / 3000)