CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes

Certification
China Lumigenex (Suzhou) Co. Ltd certification
China Lumigenex (Suzhou) Co. Ltd certification
I'm Online Chat Now

CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes

CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes
CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes

Large Image :  CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes

Product Details:
Place of Origin: China
Brand Name: Lumigenex
Certification: ISO13485, cFDA, CE
Model Number: D2006-015, D2006-050, D2006-050T
Payment & Shipping Terms:
Minimum Order Quantity: 1250 tests
Price: USD 7.0/ Test
Packaging Details: 20 tests/box, 50 tests/box
Delivery Time: 2-10 Days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: 100,000 tests/day

CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes

Description
Product Name: Ketone Body Tset Strips(Dry Chemical Method) Funtion: Diagnose Ketoacidosis, Diabetes Monitor
Technology: Dry Chemical Method Usage: In Vitro Diagnose Test In Hospital Clinic Laboratory
Format: Strip Specimen: Whole Blood
Storing Temperature: 4°C ~30°C Shelf Life: 18 Months
Reading Time: 4 Min. Compatible Equipment: Lumigenex Prochek Dry Chemistry Analyzer LP-100
Highlight:

CE Approved Ketone Body Test Strips

,

Dry Chemical Ketone Body Test Strips

CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes Rapid Test

Ketone Body Test Strip

(Dry chemical method)

 

Intended Use

This Ketone body test strip is used to quantitatively detect the concentration of ketones in the blood specimen, and diagnose ketoacidosis.

 

High ketone body levels can cause diabetic ketoacidosis (DKA), a potentially life-threatening complication. it's recommended to monitor ketone levels when patients have already been diagnosed with type 1 diabetes. Ketone testing is particularly important during periods of illness. It's also necessary to conduct blood ketone body tests if people are following a ketogenic diet and want to ensure it's in ketosis.
Regular tests at home can spot if ketone levels run too high. Then taking insulin to lower the blood sugar level or get other treatments to prevent complications.
 
It is used with Lumigenex's Pro Chek® Dry Chemistry Analyzer which provides diagnostic answers in 2 minutes.
The Dry Chemistry Analyzer should only be used by healthcare professionals for in vitro diagnostic use.

CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes 0CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes 1

 

 
 
Specification
Product Name
Ketone Body Test Strips (Dry chemical method)
Function
Diagnose Detoacidosis, Monitor Diabetes
Method
Dry Chemical
Format
Strip
Specimen
Whole Blood/ Plasma/ Serum
Usage
Daily use for professional testing in hospital, or home use for self-testing
Test Kit Components
15 / 50 Test cards
1 IC card
1 Instruction manual
Storage
For Aluminum foil bag package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively. Please use the test strip within 1 hour once the foil bag is open. For cylinder package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively. the test strips in cylinder are stable at 4°C ~30°C for 30 days tentatively once the cylinder package is opened.
Performance
Accuracy: Deviation from the quality control target value should be within ±15%.
Minimum detection limit: no higher than 0.1ug/mL.
Linearity : (0.2-50) ug/mL, the kit correlation coefficient R≥0.9900.
Repeatability: Coefficient of variation (CV) ≤15%.
Inter-batch difference: Inter-batch variation coefficient (CV) ≤15%.
Compatible Equipment
Lumigenex Prochek Dry Chemistry Analyzer LP-100
 

 

Performance
 
Accuracy
Deviation from the quality control target value should be within ±15%.
Minimum detection limit
no higher than 0.1ug/mL.
Linearity
(0.2-50) ug/mL, the kit correlation coefficient R≥0.99
Repeatability
Coefficient of variation (CV) ≤15%.
Inter-batch difference
Inter-batch variation coefficient (CV) ≤15%.

 

 

Certificates

 

CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes 2 CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes 3

 

Recommended Products

 

This Dry Chemistry Analyzer LP-100 is a quantitative detection instrument that quickly detects the sample concentration by changing the color of the test strip. It suits for solid phase carrier reagents which is used for rapid and quantitative analysis of the concentration of various analytes in blood and urine.

Features:

Designed for POC Testing
Portable handheld
Large, easy-to-read LCD
Stores up to 500 results/ test item

CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes 4

CE Approved Ketone Body Test Strips POCT Reagent Diagnose Ketoacidosis Diabetes 5

 
 

 

Contact Details
Lumigenex (Suzhou) Co. Ltd

Contact Person: Bonnie

Tel: 86-13814877381

Send your inquiry directly to us (0 / 3000)