logo
Send Message
  • English
Home ProductsRapid Test Reagent

Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab

Certification
China Lumigenex (Suzhou) Co. Ltd certification
China Lumigenex (Suzhou) Co. Ltd certification
I'm Online Chat Now

Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab

Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab
Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab

Large Image :  Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab

Product Details:
Place of Origin: China
Brand Name: Lumigenex
Certification: ISO13485, cFDA, CE
Model Number: T2018-001,T2018-005,T2018-020,T2018-050.
Payment & Shipping Terms:
Minimum Order Quantity: 1250 tests
Price: USD 5.0/ Test
Packaging Details: 20 tests/box, 50 tests/box
Delivery Time: 2-10 Days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: 100,000 tests/day

Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab

Description
Product Name: Glycosylated Hemoglobin Detection Kit (TRFIA) Funtion: Diagnose And Monitor Diabetes
Method: Time Resolved Fluorescence Immunochromatographic Assay Usage: In Vitro Diagnose Test In Hospital Clinic Laboratory
Format: Cassette Specimen: Whole Blood/ Plasma/ Serum
Storing Temperature: 2°C ~8°C Shelf Life: 18 Months
Reading Time: 4 Min. Compatible Equipment: Lumigenex Prochek Dry Chemistry Analyzer LP-100
Highlight:

Glycosylated Hemoglobin Test

,

TRFIA Glycosylated Hemoglobin Detection Kit

,

Glycosylated Hemoglobin Rapid Test

Rapid Test Kit Glycosylated Hemoglobin Detection Kit IVD Professional Test In Hospital Clinical Lab

Glycosylated Hemoglobin Detection Kit (TRFIA)

 

 

Intended Use

The Glycosylated Hemoglobin Detection Kit is intended for the clinical determination of the content of human blood for glycosylated hemoglobin.

Hemoglobin is the part of the red blood cells that carries oxygen from the lungs to the rest of your body. Glycosylated hemoglobin is the formation of hemoglobin and a combination of sugars by non-enzymatic. the combination of processes is slow and relatively irreversible, and the persistence of the life of 120 days in the red blood cells is directly proportional to the concentration of the sugar in the synthesis rate of erythrocyte surroundings. therefore, the percentage of glycosylated hemoglobin reflects the determination of the average blood sugar levels within 8-12 weeks before testing.

For people who have diabetes, the test is used to indicate how well diabetes has been controlled over the last few months. People with diabetes are advised to have this test every 3 to 6 months or more frequently if it is not under control.

 

It is used with Lumigenex's LTRIC series Time-Resolved Fluorescence Immunoassay Analyzer
The Analyzer should only be used by healthcare professionals for in vitro diagnostic use.

 

Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab 0Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab 1

 

 
 
Specification
Product Name
Glycosylated Hemoglobin Detection Kit (TRFIA)
Function
Diagnose and Monitor Diabetes
Method
Time-Resolved Fluorescence Immunochromatographic Assay
Format
Cassette
Specimen
Whole Blood/ Plasma/ Serum
Usage
Daily use for professional testing in hospital, or home use for self-testing
Test Kit Components
15 / 50 Test cards
1 IC card
1 Instruction manual
Storage
For the aluminum foil bag package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively. Please use the test kit within 1 hour once the foil bag is opened. 
Performance
Accuracy: Deviation from the quality control target value should be within ±15%.
Minimum detection limit: no higher than 0.1ug/mL.
Linearity : (0.2-50) ug/mL, the kit correlation coefficient R≥0.9900.
Repeatability: Coefficient of variation (CV) ≤15%.
Inter-batch difference: Inter-batch variation coefficient (CV) ≤15%.
Compatible Equipment
Lumigenex Time-Resolved Fluorescence Immunoassay Analyzer LTRIC-300, LTRIC-600

 

 

Test Procedure

Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab 2

Performance
 
Accuracy
Deviation from the quality control target value should be within ±15%.
Minimum detection limit
no higher than 0.1ug/mL.
Linearity
(0.2-50) ug/mL, the kit correlation coefficient R≥0.99
Repeatability
Coefficient of variation (CV) ≤15%.
Inter-batch difference
Inter-batch variation coefficient (CV) ≤15%.

 

 

Certificates

 

Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab 3 Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab 4

 

Recommended Products

 

Rapid Glycosylated Hemoglobin Detection Kit In Hospital Clinical Lab 5

Time-Resolved Fluorescence Immunoassay Analyzer LTRIC-600
 

This Dry Chemistry Analyzer LP-100 is a quantitative detection instrument that quickly detects the sample concentration by changing the color of the test strip. It suits for solid phase carrier reagents which is used for rapid and quantitative analysis of the concentration of various analytes in blood and urine.

 

Detection Projects Test Items
Diabetes HbA1C
Cardiac

CK-MB, cTnI, Myo, NT-proBNP, D-Dimer, H-FABP, sST2, Homocysteine,

cTnI/H-FABP, cTnI/CK-MB/Myo

Inflammation CRP, PCT, SAA, CRP/SAA, PCT/IL-6
Hormone 5(OH)D3, β-HCG, AMH
Gastric Function PGI/PGII
Renal Injury ACR

 

 

 
 

 

Contact Details
Lumigenex (Suzhou) Co. Ltd

Contact Person: Bonnie

Tel: 86-13814877381

Send your inquiry directly to us (0 / 3000)