Product Details:
|
Type: | Portable | Application: | Clinica/Medical Center/Hospital/Labtory |
---|---|---|---|
Accuracy: | Target Value±10% | Precision: | CV≤5.0% |
Linearity: | R²≥0.980 | Repeatability: | CV(%)≤15% |
Specimen: | 20-40uL Fingertip Blood | Color: | White |
Highlight: | hospital lipid panel analyzer,hospital portable biochemistry analyzer,40uL Fingertip Blood lipid panel analyzer |
Intelligent chronic disease management expert Dry Chemistry Analyzer LP-100
Dry Biochemical Analyzer; Biochemical Analyzer;Analyzer
1. Product Description
The dry chemistry analyzer is a smart and portable quantitative analysis instrument. The Dry Chemistry Analyzer uses the reflection spectrophotometry principle to quantitative detect the chemical components in the clinical human blood samples of whole blood, serum and plasma by testing the matched test strips manufactured by Lumigenex (Suzhou) Co., Ltd. The working principle of the dry chemistry analyzer is as follows: illuminate the colour area of the test strip with a specific wavelength light source, measure the absorbance of the test strip, capture the reflected signal strength with the photosensitive diode, and detect the content of the analyte according to the obtained AD value.
2. Specification
Product Name | Dry Chemistry Analyzer |
Specification | 1 set/box |
Weight | 116g±16g |
Size | 139(L)×76(W)×26.6(H)mm |
Sample | Blood, Urine |
Storage Temperature | 5℃~40℃ |
Storage Humidity | 20%~80% |
Certificate | ISO13485/CE/CFDA |
Precision | CV≤5.0% |
Repeatability | CV≤15% |
Output | USB, Bluetooth |
Printer | Portable Bluetooth printer (optional), additional payment if needed |
Place of Origin | Suzhou, Jiangsu, China |
MOQ | Negotiable, Accept small quantity |
Lead Time | Depends on the order, 1~15 working days |
Tips | Best to inquire for shipping details. We will contact you within 24 hours. Door to door service can be provided in some areas. |
3.Features of the instrument
Accuracy: Analyzer detects the relative deviation of
the accuracy of signal value should be the
target valve±10%
· Precision: CV≤5.0%
· Linear: Analyzer signal value range(10~90),
analyzer linear r2≥0.980
· Repeatability: CV(%)≤15%
· Difference between batch: CV(%)≤15%
Comparison table between the dry biochemical analyzer and wet biochemical analyzer | |||
No. | Name | Dry Biochemical Analyzer | Wet Biochemical Analyzer |
1 | Detection method | Reflection luminosity | Transmission photometry |
2 | Reaction carrier | Solid medium | Colourimetric cup or flow pool |
3 | Pipeline system | Non-liquid pipeline | yeah |
4 | Theoretical basis | Kubelka | Lambert-Beer |
5 | Maintain | Simple | Tedious |
6 | Reagent | Solid-phase, most of them do not need calibration, and the stability period is long. | Liquid, need calibration, a short stabilization period |
4.The advantages of dry chemistry.
High accuracy.
The sensitivity and accuracy are similar to those of typical discrete instruments.
Rapid detection.
Multilayer film technology, which can be tested immediately by adding samples, and the detection time is short.
Widely used.
Flexible use scene, suitable for laboratory departments, clinical blood stations, primary medical and health institutions, physical examination centres, etc.
Environmental protection and no pollution.
No washing, clean environmental protection waste only reagent card, easy to collect and dispose of.
Compact and lightweight.
The instrument has the advantages of simple structure, small size, and lightweight.
Easy to operate.
Non-liquid pipeline.
Storage at room temperature, no reheating, long-term stability without electrode maintenance, no need to replace electrode film.
Influencing factors of dry Chemical Analysis Technology.
1. Quality control material.
2.Storage and use of dry film reagents.
3. Working environment and temperature
5.Testing Parameter
Test items | Test Time/Sample Volume | Measurement Range (mmol/L) | Reference Range (mmol/L) |
TC |
2min 40µL(finger blood) |
2.59-11.70 | <5.18 |
HDL-C | 0.39-2.59 | ≥1.04 | |
TG | 0.50-6.00 | <1.70 | |
LDL-C | to be calculated value | <3.35 | |
TC/HDL-C | to be calculated value | <4.98 |
Dry Chemistry Analyzer Technology
Data management: Can storage 3000 data
Communication system: Matched USB Cable connect analyzer and computer Power supply: AA battery, 2pcs
Humidity: 20%-80%
Printer: Portable Bluetooth printer (optional) Output: USB, Bluetooth
Outside size Master: 139(L)×76(W)×26.6(H)mm, Error±1mm Weight: 116g±16g
7.More Pictures
Contact Person: Bonnie
Tel: 86-13814877381