Glycosylated Hemoglobin Test Kit For Diabete Diagnose By Time Resolved Fluorescence Immunochromatographic Assay

Certification
China Lumigenex (Suzhou) Co. Ltd certification
China Lumigenex (Suzhou) Co. Ltd certification
I'm Online Chat Now

Glycosylated Hemoglobin Test Kit For Diabete Diagnose By Time Resolved Fluorescence Immunochromatographic Assay

Glycosylated Hemoglobin Test Kit For Diabete Diagnose By Time Resolved Fluorescence Immunochromatographic Assay
Glycosylated Hemoglobin Test Kit For Diabete Diagnose By Time Resolved Fluorescence Immunochromatographic Assay Glycosylated Hemoglobin Test Kit For Diabete Diagnose By Time Resolved Fluorescence Immunochromatographic Assay Glycosylated Hemoglobin Test Kit For Diabete Diagnose By Time Resolved Fluorescence Immunochromatographic Assay Glycosylated Hemoglobin Test Kit For Diabete Diagnose By Time Resolved Fluorescence Immunochromatographic Assay

Large Image :  Glycosylated Hemoglobin Test Kit For Diabete Diagnose By Time Resolved Fluorescence Immunochromatographic Assay

Product Details:
Place of Origin: China
Brand Name: Lumigenex
Certification: CE,ISO13485,TFDA
Model Number: T2018-001,T2018-005,T2018-020,T2018-050.
Payment & Shipping Terms:
Minimum Order Quantity: Negotiable
Price: Negotiable
Packaging Details: Normally 5Test/Box, 25Tests/Box,50Tests/Box
Delivery Time: Depends On Order Quantity,Negotiable
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 500,000-600,000 Pcs/Day

Glycosylated Hemoglobin Test Kit For Diabete Diagnose By Time Resolved Fluorescence Immunochromatographic Assay

Description
Product Name: Glycosylated Hemoglobin Detection Kit (TRFIA) Method: TRFIA
Function: Diagnose And Monitor Diabetes Application: In Vitro Diagnose Test In Hospital Clinic Laboratory
Format: Test Cassette Specimen: Whole Blood /Serum/Plasma
Storing Temperature: 4℃-30℃ Shelf Life: 2years(24months)
Sensitivity: 93.33% Specificity: 99.16%
Compatible Instrument: Lumigenex Time-Resolved Fluorescence Immunoassay Analyzer LTRIC-600, LTRIC-300
Highlight:

covid IgM IgG rapid test kits

,

fingertip blood IgM IgG rapid test kits

,

covid antibody blood test kit

Glycosylated Hemoglobin Detection Kit (TRFIA)

 

 

Intended Use

The HbA1c test is a useful tool for diagnosing and monitoring diabetes. Hemoglobin, found in the red blood cells, is responsible for transporting oxygen from the lungs to other parts of the body. The HbA1c test measures the average amount of glucose that has bound to hemoglobin over the past three months, as this is roughly how long red blood cells typically survive in the body.

 

HbA1c results are given in percentages. Typical results are below.

Normal: HbA1c below 5.7%
Prediabetes: HbA1c between 5.7% and 6.4%
Diabetes: HbA1c of 6.5% or higher

 

It is used with Lumigenex's LTRIC series Time-Resolved Fluorescence Immunoassay Analyzer
The Analyzer should only be used by healthcare professionals and for in vitro diagnostic use.

 

 

 
 
Specification
Product Name
Glycosylated Hemoglobin Detection Kit (TRFIA)
Function
Diagnose and Monitor Diabetes
Method
Time-Resolved Fluorescence Immunochromatographic Assay
Format
Cassette
Specimen
Whole Blood/ Plasma/ Serum
Usage
Daily use for professional testing in hospital, or home use for self-testing
Test Kit Components
15 / 50 Test cards
1 IC card
1 Instruction manual
Storage
For Aluminum foil bag package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively. Please use the test strip within 1 hour once the foil bag is open. For cylinder package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively.the test strips in cylinder are stable at 4°C ~30°C for 30 days tentatively once the cylinder package is opened.
Performance
Accuracy: Deviation from the quality control target value should be within ±15%.
Minimum detection limit: no higher than 0.1ug/mL.
Linearity : (0.2-50) ug/mL, the kit correlation coefficient R≥0.9900.
Repeatability: Coefficient of variation (CV) ≤15%.
Inter-batch difference: Inter-batch variation coefficient (CV) ≤15%.
Compatible Equipment
Lumigenex Prochek Dry Chemistry Analyzer LP-100

 

Performance
 
Accuracy
Deviation from the quality control target value should be within ±15%.
Minimum detection limit
no higher than 0.1ug/mL.
Linearity
(0.2-50) ug/mL, the kit correlation coefficient R≥0.99
Repeatability
Coefficient of variation (CV) ≤15%.
Inter-batch difference
Inter-batch variation coefficient (CV) ≤15%.

 

 

Certificates

 

Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab 4

 

Recommended Products

 

Glycosylated Hemoglobin Test Kit For Diabete Diagnose By Time Resolved Fluorescence Immunochromatographic Assay 1

Time-Resolved Fluorescence Immunoassay Analyzer LTRIC-600

 

Detection Projects Test Items
Diabetes HbA1C
Cardiac

CK-MB, cTnI, Myo, NT-proBNP, D-Dimer, H-FABP, sST2, Homocysteine,

cTnI/H-FABP, cTnI/CK-MB/Myo

Inflammation CRP, PCT, SAA, CRP/SAA, PCT/IL-6
Hormone 5(OH)D3, β-HCG, AMH
Gastric Function PGI/PGII
Renal Injury ACR

 

Contact Details
Lumigenex (Suzhou) Co. Ltd

Contact Person: Bonnie

Tel: 86-13814877381

Send your inquiry directly to us (0 / 3000)