Send Message
Home ProductsDiabetes Test Kit

Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab

Certification
China Lumigenex (Suzhou) Co. Ltd certification
China Lumigenex (Suzhou) Co. Ltd certification
I'm Online Chat Now

Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab

Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab
Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab

Large Image :  Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab

Product Details:
Place of Origin: China
Brand Name: Lumigenex
Certification: ISO13485, cFDA, CE
Model Number: T2018-001,T2018-005,T2018-020,T2018-050.
Payment & Shipping Terms:
Minimum Order Quantity: 1250 tests
Price: USD 5.0/ Test
Packaging Details: 20 tests/box, 50 tests/box
Delivery Time: 2-10 Days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: 100,000 tests/day

Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab

Description
Product Name: Glycosylated Hemoglobin Detection Kit (TRFIA) Funtion: Diagnose And Monitor Diabetes
Method: Time Resolved Fluorescence Immunochromatographic Assay Usage: In Vitro Diagnose Test In Hospital Clinic Laboratory
Format: Cassette Specimen: Whole Blood/ Plasma/ Serum
Storing Temperature: 2°C ~8°C Shelf Life: 18 Months
Reading Time: 4 Min. Compatible Equipment: Lumigenex Prochek Dry Chemistry Analyzer LP-100
High Light:

Glycosylated Hemoglobin Detection Kit

,

Fluorescence Immunoassay Hemoglobin Detection Kit

Fluorescence Immunoassay Method Glycosylated Hemoglobin Detection Kit IVD Test Reagent Use In Hospital Clinical Lab

Glycosylated Hemoglobin Detection Kit (TRFIA)

 

 

Intended Use

The test for HbA1c is used to diagnose and monitor diabetes.

Hemoglobin is the part of the red blood cells that carries oxygen from your lungs to the rest of your body. An HbA1c test shows what the average amount of glucose attached to hemoglobin has been over the past three months. It's a three-month average because that's typically how long a red blood cell lives.

 

HbA1c results are given in percentages. Typical results are below.

Normal: HbA1c below 5.7%
Prediabetes: HbA1c between 5.7% and 6.4%
Diabetes: HbA1c of 6.5% or higher

 

For people who have diabetes, the test is used to indicate how well the diabetes has been controlled over the last few months. People with diabetes are advised to have this test every 3 to 6 months, or more frequently if it is not under control.

 



It is used with Lumigenex's LTRIC series Time-Resolved Fluorescence Immunoassay Analyzer
The Analyzer should only be used by healthcare professionals and for in vitro diagnostic use.

 

Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab 0Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab 1

 

 
 
Specification
Product Name
Glycosylated Hemoglobin Detection Kit (TRFIA)
Function
Diagnose and Monitor Diabetes
Method
Time Resolved Fluorescence Immunochromatographic Assay
Format
Cassette
Specimen
Whole Blood/ Plasma/ Serum
Usage
Daily use for professional testing in hospital, or home use for self-testing
Test Kit Components
15 / 50 Test cards
1 IC card
1 Instruction manual
Storage
For Aluminum foil bag package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively. Please use the test strip within 1 hour once the foil bag is open. For cylinder package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively.the test strips in cylinder are stable at 4°C ~30°C for 30 days tentatively once the cylinder package is opened.
Performance
Accuracy: Deviation from the quality control target value should be within ±15%.
Minimum detection limit: no higher than 0.1ug/mL.
Linearity : (0.2-50) ug/mL, the kit correlation coefficient R≥0.9900.
Repeatability: Coefficient of variation (CV) ≤15%.
Inter-batch difference: Inter-batch variation coefficient (CV) ≤15%.
Compatible Equipment
Lumigenex Prochek Dry Chemistry Analyzer LP-100

 

 

Test Procedure

Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab 2

Performance
 
Accuracy
Deviation from the quality control target value should be within ±15%.
Minimum detection limit
no higher than 0.1ug/mL.
Linearity
(0.2-50) ug/mL, the kit correlation coefficient R≥0.99
Repeatability
Coefficient of variation (CV) ≤15%.
Inter-batch difference
Inter-batch variation coefficient (CV) ≤15%.

 

 

Certificates

 

Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab 3 Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab 4

 

Recommended Products

 

Glycosylated Hemoglobin Detection Kit Use In Hospital Clinical Lab 5

Time-Resolved Fluorescence Immunoassay Analyzer LTRIC-600
 

This Dry Chemistry Analyzer LP-100 is a quantitative detection instrument that quickly detects the sample concentration by changing the color of the test strip. It suits for solid phase carrier reagents which is used for rapid and quantitative analysis of the concentration of various analytes in blood and urine.

 

Detection Projects Test Items
Diabetes HbA1C
Cardiac

CK-MB, cTnI, Myo, NT-proBNP, D-Dimer, H-FABP, sST2, Homocysteine,

cTnI/H-FABP, cTnI/CK-MB/Myo

Inflammation CRP, PCT, SAA, CRP/SAA, PCT/IL-6
Hormone 5(OH)D3, β-HCG, AMH
Gastric Function PGI/PGII
Renal Injury ACR

 

 

 
 

 

Contact Details
Lumigenex (Suzhou) Co. Ltd

Contact Person: Bonnie

Tel: 86-13814877381

Send your inquiry directly to us (0 / 3000)