Product Details:
|
Product Name: | Dry Chemistry Analyzer | Specification: | 1 Set/box |
---|---|---|---|
Certificate: | CE/ISO13485/cFDA | Weight/Size: | 116g±16g/139(L)×76(W)×26.6(H)mm |
Shelf Life: | 5 Years | Place Of Origin: | Jiangsu,China |
Precision: | CV≤5.0% | Repeatability: | CV≤15% |
Temperature: | 5℃~40℃ | Humidity: | 20%~80% |
After Sales Service: | One Year Warranty | Output: | USB, Blueteeth |
Printer: | Portable Bluetooth Printer (Optional) | OEM: | Available |
Highlight: | 15 Minutes Uric Acid Meter,Uric Acid Meter Dry Chemistry Method,15 Minutes Uric Acid Test Strips |
Test Time 15 Minutes Rapid Detect Uric Acid Meter For Hospital Clinical Home Use Dry Chemistry Analyzer
Uric Acid Test Strip (Dry Chemistry method)
PRODUCT NAME
Lipid Panel Test Strips (Dry chemical method)
PACKING SPECIFICATION
15 tests/ kit; 24 tests/kit; 50 tests/ kit
INTENDED USE
The Lipid Panel Test Strips are intended to measure cholesterol (TC), HDL cholesterol (HDL-c), and triglycerides (TG) in whole blood.
Blood lipid is the general name of lipid substances contained in the blood. Hyperlipidemia refers to one or more levels of blood lipid components such as plasma cholesterol, triglyceride, and total fat that exceed the normal standard. The main harm of hyperlipidemia is atherosclerosis, which leads to many related diseases, among which the most common fatal disease is coronary heart disease. The combined detection of three blood lipids (total cholesterol, high-density lipoprotein cholesterol and triglyceride) can help to provide a clinical reference for the diagnosis and treatment of lipoprotein metabolism disorders such as diabetes, atherosclerosis, nephropathy, liver disease, and coronary heart disease. Currently, the common clinical methods to detect the content of total cholesterol and triglyceride in blood samples include enzymatic method, chemical method, and methods based on high-performance liquid chromatography.
PRINCIPLES OF THE TEST
When blood is applied to a test strip, the blood reacts to produce a color that is read by a Dry Chemical Analyzer using reflectance
photometry. The amount of color produced is proportional to the concentration. The enzymatic reactions that occur are listed below
Cholesterol ester + H2O cholesterol esterase Cholesterol + fatty acid
Cholesterol + H2O + O2 cholesterol oxidase Cholesterol-4-en-3-one + H2O2
2H2O2+ 4-AAP+Disubstituted Aniline peroxidase Quinoneimine dye + 4H2O
Specification
Product Name | Dry Chemistry Analyzer LP-100 |
Specification | 1 set/box |
Weight | 116g±16g |
Size | 139(L)×76(W)×26.6(H)mm |
Sample | Blood, Urine |
Storage Temperature | 5℃~40℃ |
Storage Humidity | 20%~80% |
Certificate | ISO13485/ CE/ cFDA |
Precision | CV≤5.0% |
Repeatability | CV≤15% |
Output | USB, Bluetooth |
Printer | Portable Bluetooth printer (optional), additional payment if needed |
Place of Origin | Suzhou, Jiangsu, China |
MOQ | Negotiable, Accept small quantity |
Lead Time | Depends on the order, 1~15 working days |
Tips | Best to inquire for shipping details. We will contact you within 24 hours. Door to door service can be provided in some areas. |
Composition
Product Description
Use matched test strips manufactured by Lumigenex to quantitatively analyze clinical chemical components in human whole blood, serum, and plasma with reflection spectrophotometry.
Features and Advantages
Applicable standard
Performance
More Pictures