Product Details:
|
Product Name: | Cardiac Troponin I/ Heart-type Fatty Acid Binding Protein (cTnI/ H-FABP) Combo Test Kit (TRFIA) | Funtion: | Cardiac Marker |
---|---|---|---|
Technology: | Time Resolved Fluorescence Immunochromatographic Assay (TRFIA) | Usage: | Vitro Diagnostic Reagent For Hospital Clinic Laboratory |
Format: | Strip, Cassette | Specimen: | Whole Blood, Plasma, Serum |
Storing Temperature: | 2℃-8℃ | Shelf Life: | 18 Months |
Reading Time: | 15 Min. | Compatible Equipment: | Lumigenex TRFIA Analyzer LTRIC-600, LTRIC-1000 |
Highlight: | H-FABP Quantitative Test Kit,H-FABP Rapid Test Kit |
Easy Operation Rapid Test Kit CTnI/H-FABP Quantitative Test Kit Point Of Care Professional Test
Cardiac Troponin I/ Heart-type Fatty Acid Binding Protein (cTnI/ H-FABP) Combo Test Kit (TRFIA)
Cardiac Troponin I/ Heart-type Fatty Acid Binding Protein (cTnI/ H-FABP) Combo Test Kit is suitable for quantitative detection of cardiac troponin I and The Cardiac fatty acid binding protein in human serum/plasma/whole blood in vitro.
The test of cTnI concentration is intended to be used as an aid in the diagnosis of acute myocardial infarction (AMI), risk stratification of the acute coronary syndrome (ACS), and monitoring of myocardial damage (1-3).
The Cardiac fatty acid binding protein can be used not only as an early marker of AMI but also as an ideal diagnostic marker for recurrence of myocardial infarction. At present, the application of cardiac fatty acid binding protein mainly includes the following aspects: early diagnosis AMI evaluation of myocardial infarction area, evaluation of early myocardial microinjury, evaluation of myocardial ischemia-reperfusion, evaluation of prognosis of heart failure, etc.
1. Assess infarct size and ACS risks
2. Bio-marker for monitoring the treatment of AMI
3. Diagnosis of acute myocardial infarction
4. 15-20 times more cardiac specific than myoglobin
5. Diagnosis of pulmonary embolism (PE), coronary artery bypass surgery (CABG), and cerebrovascular disease
1. Advanced: time-resolved fluorescence immunoassay quantitative chromatography
2. Quantitative: quantitative detection of cardiac troponin I (cTnI) and Heart fatty-acid binding protein (H-FABP)
3. Accurate: well correlated with imported hemiluminescence reagent (r> 0.975)
4. High sensitivity: lower detection limit <0.05 ng/mL (cTnI) and <1.0 ng/mL (H-FABP)
5. Simple: simple operation, suitable for bedside detection
6. Widely applicable: outpatient laboratory, emergency laboratory, medical center, cardiology, ICU, etc.
Accuracy | Deviation from the quality control target value should be within ±15%. |
Minimum detection limit | no higher than 0.1ug/mL. |
Linearity | (0.2-50) ug/mL, the kit correlation coefficient R≥0.99 |
Repeatability | Coefficient of variation (CV) ≤15%. |
Inter-batch difference | Inter-batch variation coefficient (CV) ≤15%. |