Product Details:
|
Product Name: | High Sensitivity MYO Quantitative Detection Kit (TRFIA) | Specification: | 20 Tests/box |
---|---|---|---|
Certificate: | ISO13485, CFDA | Specimen: | Whole Blood, Plasma, Serum |
Storing Temperature: | 2℃-8℃ | Shelf Life: | 18 Months |
Place Of Origin: | Jiangsu,China | Production Capacity: | 100,000 Tests/day |
Technology: | TRFIA | OEM: | Available |
Highlight: | MYO point of care testing kits,cFDA point of care testing kits |
High sensitivity cFDA approved MYO Quantitative Detection Kit (TRFIA)
1. Product Description
Principle:
Based on time-resolved fluorescence immunochromatography, the Myoglobin (MYO) Test Kit (Time Resolved Fluorescence Immunochromatographic Assay)was used to quantitatively determine the concentration of MYO in blood samples. The sample was added to the reagent card, and the MYO in the sample was coupled with the fluorescent microspheres on the marker pad to form a complex against human MYO monoclonal antibody, and was captured to form a double antibody sandwich complex. As a result, the more MYO in the sample, the more complex accumulation on the detection band. The excess unreacted fluorescent microspheres continued to be chromatographic to the control line. fluorescence intensity on the detection line reflects the content of captured MYO in the sample. The concentration of MYO in the sample was quantitatively reflected by the LTRIC-300/ LTRIC-600/LTRIC-1000 of time-resolved fluorescence immunoassay..
Intended Use:
This Myoglobin (MYO) Test Kit (Time Resolved Fluorescence Immunochromatographic Assay) is suitable for quantitative detection of Myoglobin(abbreviated as MYO below)in human Serum/plasma/whole blood in vitro.
Myoglobin is an early marker of myocardial necrosis. Clinical studies have shown that myoglobin can be detected within 1 hour of onset and peak in 4~5 hours. But in many cases myoglobin levels rise, such as skeletal muscle injury, skeletal muscle or neuromuscular dysfunction, cardiac shunt surgery, renal failure, and high-intensity physical exercise. Therefore, the elevation of myoglobin must be used in the auxiliary diagnosis of acute myocardial infarction (AMI) together with the detection of other cardiac markers, electrocardiogram (ECG), clinical symptoms and signs, etc. The detection platform of this project mainly includes chemiluminescence technology, immunocompetency technology, colloidal gold technology, immunofluorescence technology, time-resolved fluorescence technology and so on..
2. Specification
Product Name | High sensitivity cFDA approved MYO Quantitative Detection Kit (TRFIA) |
Specification | 20 tests/box |
Sample | Whole blood, Plasma, Serum |
Storage Temperature | 2℃-8℃ |
Certificate | ISO13485/cFDA |
Place of Origin | Suzhou, Jiangsu, China |
MOQ | Negotiable, Accept small quantity |
Lead Time | Depends on the order, 1~15 working days |
Tips | Best to inquire for shipping details. We will contact you within 24 hours. Door to door service can be provided in some areas. |
3. High sensitivity cFDA approved MYO Quantitative Detection Kit (TRFIA) Main component
4. Storage conditions and expiry date?
5. More Pictures