Product Details:
|
Product Name: | High Sensitivity Cardiac Troponin I Quantitative Detection Kit (TRFIA) | Technology: | TRFIA |
---|---|---|---|
Specimen: | Whole Blood, Plasma, Serum | Storing Temperature: | 2℃-8℃ |
Shelf Life: | 18 Months | Place Of Origin: | Jiangsu,China |
Production Capacity: | 100,000 Tests/day | Compatible Equipment: | Lumigenex TRFIA Analyzer LTRIC-600, LTRIC-1000 |
High Light: | poc rapid strep test,poc kits |
High sensitivity cFDA approved Cardiac Troponin I Quantitative Detection Kit (TRFIA)
Test Principle
The Cardiac Troponin I Test Kit is a single use time resolved fluorescence immunoassay device designed to quantify the cTnI level in human serum and heparin anticoagulated whole blood or plasma specimens. The test kit contains two monoclonal antibodies against cTnI. One of the antibodies is covalently bound to the surface of the fluorescent microspheres. Antibody labeled microspheres are sprayed on conjugate pad, the other antibody is immobilized on the test line of detection pad. After the addition of diluted whole blood/plasma specimen, cTnI in the specimen reacts with the fluorescent microsphere coupled with cTnI mouse antihuman monoclonal antibody to form fluorescent antigen-antibody complex, this complex flows to the test line and captured by the other antibody to form fluorescent antibody sandwich complex. So the more cTnI in the specimen, the more fluorescent antibody sandwich complex accumulate in the test line. The fluorescence from the test kit is collected and calculated by Time-resolved Fluorescence Immunoanalyzer to quantify the concentration of cTnI in the specimen.
1. "Golden Standard" to diagnose myocardial infarction (MI)
2. Assess infarct size and ACS risks
3. Bio-marker for monitoring the treatment of AMI
Intended Use
The Cardiac Troponin I (cTnI) Test Kit is suitable for use in vitro with Time-Resolved Fluorescence Immunoanalyzer reader to rapidly quantify the concentration of cTnI in human serum and heparin anticoagulated whole blood or plasma specimens at a point of care site. The test is intended to be used as an aid in diagnosis of acute myocardial infarction (AMI), risk stratification of acute coronary syndrome (ACS), and monitoring of myocardial damage (1-3).
Specification
Product Name |
High sensitivity cFDA approved Cardiac Troponin I Quantitative Detection Kit (TRFIA) |
Specification | 20 tests/box |
Sample | Whole blood, Plasma, Serum |
Storage Temperature | 2℃-8℃ |
Certificate | ISO13485/cFDA |
Place of Origin | Suzhou, Jiangsu, China |
MOQ | Negotiable, Accept small quantity |
Lead Time | Depends on the order, 1~15 working days |
Tips | Best to inquire for shipping details. We will contact you within 24 hours. Door to door service can be provided in some areas. |