logo
Send Message
  • English
Home ProductsCardiac Marker Test Kit

High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker

Certification
China Lumigenex (Suzhou) Co. Ltd certification
China Lumigenex (Suzhou) Co. Ltd certification
I'm Online Chat Now

High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker

High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker
High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker

Large Image :  High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker

Product Details:
Place of Origin: China
Brand Name: Lumigenex
Certification: ISO13485, cFDA, CE
Model Number: T2003-020, T2003-050
Payment & Shipping Terms:
Minimum Order Quantity: 1250 tests
Price: USD 2.0/ Test
Packaging Details: 20 tests/box, 50 tests/box
Delivery Time: 2-10 Days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: 100,000 tests/day

High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker

Description
Product Name: N-Terminal Pro-Brain Natriuretic Peptide (NT-proBNP) Test Kit (TRFIA) Funtion: Cardiac Marker
Technology: Time Resolved Fluorescence Immunochromatographic Assay (TRFIA) Usage: Vitro Diagnostic Reagent
Format: Strip, Cassette Specimen: Whole Blood, Plasma, Serum
Storing Temperature: 4℃-30℃ Shelf Life: 18 Months
Reading Time: 15 Min. Compatible Equipment: Lumigenex TRFIA Analyzer LTRIC-600, LTRIC-1000
Highlight:

poc rapid strep test

,

poc kits

High sensitivity cFDA approved N-Terminal pro-Brain Natriuretic Peptide (NT-proBNP) Test Kit (TRFIA)

 
Intended Use

The N-terminal-pro-Brain Natriuretic Peptide(NT-proBNP )Test Kit is suitable for use in vitro with Time-Resolved Fluorescence Immunoanalyzer reader to rapidly quantify the concentration of NT-proBNP in human serum and anticoagulated whole blood or plasma specimens at a point of care site. The test is intended to be used as an aid in the diagnosis of congestive heart failure and the risk stratification of the acute coronary syndrome and congestive heart failure(1-3).

 

 

Principle


The NT-proBNP Test Kit is a single-use time-resolved fluorescence immunoassay device designed to quantify the NT-proBNP level in human serum and anticoagulated whole blood or plasma specimens. The test kit contains two monoclonal antibodies against NT-proBNP. One of the antibodies is covalently bound to the surface of the fluorescent microspheres. Antibody-labeled microspheres are sprayed on the conjugate pad, the other antibody is immobilized on the test line of the detection pad. After the addition of diluted whole blood, serum, or plasma specimen, NT-proBNP in the specimen reacts with the fluorescent microsphere coupled NT-proBNP mouse antihuman monoclonal antibody to form fluorescent antigen-antibody complex, this complex flows to the test line and is captured by the other antibody to form fluorescent antibody sandwich complex. So the more NT-proBNP in the specimen, the more fluorescent antibody sandwich accumulates in the test line. The fluorescence from the test kit is collected and calculated by LTRIC 600 Time-resolved Fluorescence Immunoanalyzer to quantify the concentration of NT-proBNP in the specimen.

 

High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker 0High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker 1
Specification

Product Name
N-Terminal pro-Brain Natriuretic Peptide (NT-proBNP) Test Kit (TRFIA)
Method
Time-Resolved Fluorescence Immunochromatographic Assay (TRFIA)
Certificates
ISO13495, CE
Usage
Vitro Diagnostic Reagent
Function
Cardiac Marker
Specimen
Whole Blood/ Serum/ Plasma
Test Kit Components
20 / 50 Test cards
20 / 50 Sample buffer
1 IC card
1 Instruction manual
Storage & Shelf Life
4℃-30℃, 18 months
Compatible Equipment
Lumigenex Time-resolved Fluorescence Immunoanalyzer LTRIC-600, LTRIC-1000
Test Procedure

High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker 2
Performance

Accuracy
Deviation from the quality control target value should be within ±15%.
Minimum detection limit
no higher than 0.1ug/mL.
Linearity
(0.2-50) ug/mL, the kit correlation coefficient R≥0.99
Repeatability
Coefficient of variation (CV) ≤15%.
Inter-batch difference
Inter-batch variation coefficient (CV) ≤15%.

 

Recommended Products


High Sensitivity (NT-proBNP) Test Kit (TRFIA) congestive heart failure Cardiac Marker 3

 
Time-Resolved Fluorescence Immunoassay Analyzer
 
Product model LTRIC-600, LTRIC-1000
 
Test Menu
Cardiovascular Disease: cTnI, CK-MB, Myo, cTnI/CK-MB/MYO, H-FABP, cTnI/H-FABP, NT-proBNP, D-Dimer
Inflammation: PCT, CRP, SAA, CRP/SAA
Renal Injury: NGAL, ACR
Others: PGI/PGII, β-HCG, Influenza A+B
 
Highlights
* Nano-Enhanced TRIFA
* Rapid and accurate quantitative POCT Platform
* Repeatability: CV<10%
* Stability: σ ≤ 10% * Accuracy: Δn ≤ 10% * Linearity: r ≥ 0.99
 
Detection Projects
Test Strips and Cassettes (with links)

Diabetes

HbA1C, Glucose,  Ketone Body

Hyperlipidemia

Lipid Panel

Anemia

Hemoglobin

Cardiac

CK-MB, cTnI, Myo, NT-proBNP, D-Dimer, H-FABP, sST2, Homocysteine,

cTnI/H-FABP, cTnI/CK-MB/Myo

Inflammation

CRP,  PCT,  SAA,  CRP/SAA,  PCT/IL-6

Hormone

5(OH)D3, β-HCG, AMH

Gastric Function

PGI/PGII

Liver Injury

Aspartate Transaminase, Alanine Aminotransferase

Renal Injury

mALB, Creatinine, NGAL, ACR(TRFIA), ACR(Colloidal Gold)

Gout

Uric Acid

Others

Influenza A+B Combo, Influenza A+B/RSV Combo

Monkeypox CG, Monkeypox IgG/IgM, Monkeypox RT-PCR

 

Contact Details
Lumigenex (Suzhou) Co. Ltd

Contact Person: Bonnie

Tel: 86-13814877381

Send your inquiry directly to us (0 / 3000)

Other Products