Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer

Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer
Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer

Large Image :  Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer

Product Details:
Place of Origin: China
Brand Name: Lumigenex
Certification: ISO13485, cFDA, CE
Model Number: D2004-015, D2004-050, D2004-050T.
Payment & Shipping Terms:
Minimum Order Quantity: 1250 tests
Price: USD 7.0/ Test
Packaging Details: 20 tests/box, 50 tests/box
Delivery Time: 2-10 Days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: 100,000 tests/day

Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer

Description
Product Name: Homocysteine Test Strips(Dry Chemical Method) Funtion: Screen For Heart Disease
Method: Dry Chemical Method Usage: In Vitro Diagnose Test In Hospital Clinic Laboratory
Format: Strip Specimen: Whole Blood/ Plasma/ Serum
Storing Temperature: 4°C ~30°C Shelf Life: 18 Months
Reading Time: 4 Min. Compatible Equipment: Lumigenex Prochek Dry Chemistry Analyzer LP-100
Highlight:

Dry Chemistry Analyzer Homocysteine Test Strips

,

Homocysteine Test Strips

,

Dry Chemistry Analyzer HCY Rapid Test

Cardiac Disease Heart Disease Biomarker Homocysteine Test Strips HCY Rapid Test With Dry Chemistry Analyzer

Homocysteine Test Strips

(Dry chemical method)

 

Intended Use

This homocysteine test strip can quantitatively measure the amount of homocysteine in the blood specimen.

Homocysteine is a type of amino acid. The human body naturally makes homocysteine. But at high levels, it can damage the lining of arteries. It can encourage blood clotting. This may raise the risk of coronary artery disease, heart attacks, blood clots, and strokes. High levels of homocysteine in the blood may be a sign of a vitamin deficiency, heart disease, or a rare inherited disorder.

It is used with Lumigenex's Pro Chek® Dry Chemistry Analyzer which provides diagnostic answers in 2 minutes.
The Dry Chemistry Analyzer should only be used by healthcare professionals for in vitro diagnostic use.

 

Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer 0Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer 1

 

 
 
Specification
Product Name
Homocysteine Test Strips(Dry chemical method)
Function
Screen for coronary artery disease
Method
Dry Chemical
Format
Strip
Specimen
Whole Blood/ Plasma/ Serum
Usage
Daily use for professional testing in hospital, or home use for self-testing
Test Kit Components
15 / 50 Test cards
1 IC card
1 Instruction manual
Storage
For Aluminum foil bag package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively. Please use the test strip within 1 hour once the foil bag is open. For cylinder package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively.the test strips in cylinder are stable at 4°C ~30°C for 30 days tentatively once the cylinder package is opened.
Performance
Accuracy: Deviation from the quality control target value should be within ±15%.
Minimum detection limit: no higher than 0.1ug/mL.
Linearity : (0.2-50) ug/mL, the kit correlation coefficient R≥0.9900.
Repeatability: Coefficient of variation (CV) ≤15%.
Inter-batch difference: Inter-batch variation coefficient (CV) ≤15%.
Compatible Equipment
Lumigenex Prochek Dry Chemistry Analyzer LP-100
 

 

Performance
 
Accuracy
Deviation from the quality control target value should be within ±15%.
Minimum detection limit
no higher than 0.1ug/mL.
Linearity
(0.2-50) ug/mL, the kit correlation coefficient R≥0.99
Repeatability
Coefficient of variation (CV) ≤15%.
Inter-batch difference
Inter-batch variation coefficient (CV) ≤15%.

 

 

Certificates

 

Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer 2 Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer 3

 

Recommended Products

 

This Dry Chemistry Analyzer LP-100 is a quantitative detection instrument that quickly detects the sample concentration by changing the color of the test strip. It suits for solid phase carrier reagents which is used for rapid and quantitative analysis of the concentration of various analytes in blood and urine.

Features:

Designed for POC Testing
Portable handheld
Large, easy-to-read LCD
Stores up to 500 results/ test item

Cardiac Disease Homocysteine HCY Rapid Test With Dry Chemistry Analyzer 4